Appliances Direct
Laptops Direct
Drones Direct
Better Bathrooms
Furniture 123
Dehumidifiers
Outdoor Living
Aircon
My Account

Track order Trade enquiries Public Sector enquiries
Inc. VAT vat switch show inc Ex. VAT Inc. VAT vat switch show ex Ex. VAT
£ currency switch £ currency switch

Neff D16BS01S0B 60cm Conventional Cooker Hood Black

SKU: D16BS01S0B Quickfind Code: 929513
SAVE 26%
Energy Label
Energy rating E

Unsure what extraction rate you need? Use our handy calculator

Extraction Rate Calculator

Use our handy calculator, to help figure out exactly what extraction rate you require for your kitchen.

What are the kitchen dimensions?

What is an extraction rate?

Cooker hoods come with different extraction rates, which determine how quickly the air is changed in the kitchen. It’s recommended that your cooker hood should change the air around 10 times per hour. So, the larger the kitchen the higher the extraction rate.

The extraction rate your kitchen needs all depends on its size. The faster the extraction rate the faster the air will be cleaned, although the noise level may go up, so faster isn’t always better. Take a look at how to work out your extraction rate above.

This product is no longer available.

Features
  • For wall mounted installation or suspended beneath a reduced height wall cupboard
  • LED display
  • 1 x halogen lamps
  • 1 metal grease filter cassette
  • Fleece filter
  • 3 power levels
Design
  • Black
  • Black with glass canopy
  • 60 cm wide Conventional hood
  • Standard design
  • Slide control operation
  • Mechanical controls
  • Light Colour: warm white
Performance/technical information
  • Suitable for ducted extraction and recirculation
  • For recirculated extraction charcoal filter (accessory) needed
  • Twin channel high performance fan motor
  • In recirculation operation chimless use possible
  • Extraction rate according to EN 61591: max. 240 m³/h
  • Power rating: 153 W
  • Noise level at maximum normal setting: 57 dB (A); equivalent to 71 dB (A) re 1 pW according to EN 60704-2-13
  • Noise level according to EN 60704-3 and EN 60704-2-13 at maximum normal setting: extraction rate: 71 dB (A) re 1pW
  • Noise max. Normal Level: 71 dB*
  • Light Intensity: 44 lux
  • Colour Temperature: 2700 K
  • Electrical cable lenght 1.5 m
  • Diameter pipe Ø 120 mm (Ø 100 mm enclosed)
  • Dimensions exhaust air (HxWxD): 150-150 x 600 x 482 mm
  • Dimensions recirculating (HxWxD): 150-150 x 600 x 482 mm
  • Energy Efficiency Class: E*
  • Blower Efficiency Class: F*
  • Lighting Efficiency Class: G*
  • Grease Filtering Efficiency Class: D*
  • Average Energy Consumption: 91.3 kWh/year*
  • Optional accessories
  • Recirculating kit
 

Question from Mrs S Oxley: Asked on 18/01/2016 Is this product rear vented or top vented?

Answer from jasoncooper: Answered on 19/01/2016
top.

You may also like

Recently viewed


Back to top